介绍世界上第一台旨在满足 Web 伸缩性能要求的服务器:安全地支持数千万名用户,并且将功耗降低了 2 倍,空间减少了 4 倍。 Sun SPARC Enterprise T5120 服务器在 Web 伸缩和节省方面具有不可思议的效果。 它也是最开放的平台,每处理器多达八个内核和 64 个线程,全部采用紧凑的 1RU 结构。
4-, 6-, and 8-core 1.2-GHz or 8-core 1.4-GHz UltraSPARC T2 processor
Up to 8-core, 64 threads per processor
Up to 64 GB of memory
Up to four 73- or 146-GB SAS disks
技术规格 获取
技术规格
主要应用领域
Web serving
Streaming media
Security applications
Java Application Servers
Java Virtual Machines
Network infrastructure
SOA and business integration platforms
Compute and network node
Consolidation and virtualization
Processor
4-, 6-, and 8-core 1.2-GHz or 8-core 1.4-GHz UltraSPARC T2 Processors; one Processor per system, maximum 64 threads
体系结构
SPARC V9 architecture, ECC protected
Cache per Processor:
4 MB integrated L2
Other Processor key features:
Under 95 W (nominal) and fewer than 2 W per thread
Dual, multithreaded, 10 Gb Ethernet PCIe integrated onto chip
Eight floating point units
On board cryptography Supporting 10 embedded security industry standard ciphers including: DES, 3DES, AES, RC4, SHA1, SHA256, MD5, RSA to 2048 key, ECC,CRC32
主要 RAS 功能
主要 RAS 功能
热插拔磁盘驱动器
冗余热插拔电源
冗余热插拔风扇
环境监控
纠错和奇偶校验
易于更换的组件
内部硬件驱动器镜像 (RAID 1)
RAID 0 和 1 支持
主内存
Sixteen DIMM Slots, system maximum of 64 GB; Support for 1 GB, 2 GB, and 4 GB DIMMs; minimum of 4 GB (4x 1 GB)
标准/集成接口
Network: Four 10/100/1000 Mbps Ethernet
Expansion bus: 1x 8 lane PCIe and 2x 4 lane PCIe OR XAUI
USB: Four 2.0 USB Ports
大容量存储和介质
Internal disk: up to four 73- or 146-GB SAS disks
Internal DVD: one slimline DVD-ROM/CD-RW
External storage:
Sun offers a complete line of best-in-class, innovative storage hardware, software, and solutions?including tape drives, tape libraries, disk storage systems, data management software, and more?along with renowned world-class service and Support Our data management solutions help customers share information more effectively, manage data more efficiently to save money, and reduce risk by making sure that data is available, recoverable, and compliant. For more information, please see sun.com/storagetek
软件
Operating system
Solaris 10 Operating System 8/07
Preloaded software
The latest Solaris 10 Operating System 8/07
Sun Java Enterprise System Release 5 (90-day evaluation)
Logical Domains Manager 1.0.1
Logical Domains MIB 1.0.1
Sun Studio 12
Cool Tools for CoolThreads servers
电源
Two hot-swappable AC 650 W or DC 660 W Power Supply units (PSUs) providing N+1 redundancy
环境
Operating input voltage range: 100 to 240 VAC, 50-60 Hz
Maximum operating input current:
5 A at 100 to 120 VAC
2.5 A at 200 to 240 VAC
Minimum config idle/peak power: 216 / 285W
Maximum config idle/peak power: 384 / 641W
Maximum heat dissipation: 750 BTU/hr (791 KJ/hr)
Operating Temperature:
Operating: Sea level to 3000 ft (900m)
Non-Operating: 41F to 95F (5C to 35C) -40 to 65C
Above 3000 ft (900m)
Operating: Decrease maximum temperature as altitude increases, 1.6F/1000 ft(1C/ 300m)
Operating: -40 to 65C
Relative Humidity:
Operating: 10 to 90% RH, non-condensing
Non-Operating: 93% RH 35C
Operating: 27C wet bulb, IEC 60068-2-3&56
Non-Operating: non-condensing IEC 60068-2-3&56
Altitude:
Operating: 0-3,000 meters (0-10,000 feet)
Non-Operating: 0-12,000 meters
Operating: IEC 60068-2-13
Non-Operating: (0-40,000 feet)
Non-Operating: IEC 60068-2-3&56
Vibration:
Operating: 0.15G (z-axis), 0.10G (x,y axis)
Non-Operating: 0.5G (z-axis), 0.25G
Operating: 5-500 Hz
Non-Operating: (x,y axis) S5-500Hz sine
Shock:
Operating: 3Gs peak 11 milliseconds,half-sine pulse, IEC 60068-2-3&56
Non-Operating: 1-inch roll-off front to back, 20mm step threshold testing of castors at 0.75m/s
尺寸和重量
Height: 44.35 mm (1.746 inches); 1 rack unit
Width: 425.45 mm (16.75 inches)
Depth: 714.44 mm (28.125 inches)
Weight: Approximate 16.55 kg (36.5 lb.)
Description: Clearance, front of system - Specification: 36 inches (91 cm)
Description: Clearance, rear of system - Specification: 36 inches (91 cm)
Description: LwAd (1 B = 10 dB) - Mode: Operating acoustic noise - Specification: 7.0 B
Mode: Idling acoustic noise - Specification: 7.0 B
LpAm (bystander positions):
Operating acoustic noise: 59 dB
Idling acoustic noise: 59 dB
Ambient Temperature: An ambient temperature range of 21C (69.8F) to 23C (73.4F) is optimal for server reliability. At 22C (71.6F) it is easy to maintain safe relative humidity levels. Operating in this temperature range provides a buffer if the environmental Support systems fail.
Ambient Relative Humidity - Ambient relative humidity levels between 45% and 50% are the most suitable for data processing operations in order to:
Prevent corrosion
Provide an operating time buffer in the event of environmental control system failure
Help avoid failures caused by the intermittent interferences from static discharges that occur when relative humidity is too low
Electrostatic discharge (ESD) is easily generated and less easily dissipated in areas where the relative humidity is below 35% and becomes critical when levels drop below 30%.
EMC
USA - FCC Class A
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This equipment may not cause harmful interference.
2) This equipment must accept any interference that may cause undesired operation.
European Union: This equipment complies with the following requirements of the EMC Directive 2004/108/EC
As Information Technology Equipment (ITE) Class A per (as applicable):
EN 55022:2006, Class A
EN 61000-3-2:2000 +A2:2005, Pass
EN 61000-3-3:1995 +A1:2001, Pass
EN 55024:1998 +A1: 2001 +A2:2003 Required Limits:
IEC 61000-4-2, 4 kV (Direct), 8 kV (Air)
IEC 61000-4-3, 3 V/m
IEC 61000-4-4, 1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
IEC 61000-4-5, 1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines
IEC 61000-4-6, 3 V
IEC 61000-4-8, 1 A/m
IEC 61000-4-11, Pass
安全性
This equipment complies with the following requirements of Low Voltage Directive 2006/95/EC:
EC Type Examination Certificates:
EN 60950-1:2001, 1st Edition - Certificate No. US/11738/UL
IEC 60950-1:2001, 1st Edition - CB Scheme Certificate
No. US/11738/UL
Evaluated to all CB Countries:
UL 60950-1:2003, CSA C22.2 No. 60950-03
File: E138989 Vol. 59 Sec.
保修 有关保修条款和条件,请访问以下保修网站:http://www.sun.com/service/warranty/product_warranty_chart.html