Polypropylene(PP) insulation, Nitrile rubber(NBR) jacket, Full galvanized steel (or stainless steel or Monel) tape armour.QYPNY SUBMERGIBLE POWER CABLE
Description
Performing Criterion
IEEE1017,IEEE1018,IEEE1019
Application Range
This cable is applicable for use in Electricity Submergible Pump Units with rated voltage less than 3kV or 6kV. The permissible working temperature is 90℃(194℉). The cable has the excellent ability of oil-resistance and corrosion-resistance.
Cable’s Cross Section Chart
● Specification and Parameters
Phase
Cross
Section
mm2 Conductor
Diameter
mm DC Resistance
at 20℃
≤Ω/km Insulation
Thickness
mm Jacket
Thickness
mm Overall Size and Weight
3kV 6kV
Not tinned Tinned 3kV 6kV mm kg/km mm kg/km
3 16 1/4.62 1.15 1.16 2.0 2.3 2.0 27 1381 29 1480
3 20 1/5.19 0.84 0.86 2.0 2.3 2.0 28 1555 31 1650
3 33 1/6.54 0.54 0.56 2.0 2.3 2.0 32 2060 34 2170
3 42 1/7.35 0.43 0.44 2.0 2.3 2.0 34 2382 37 2500
Index of Performance
Cross
Section Conductor
Diameter
mm 3kV
Insulation
Resistance
MΩ·km 3kV
Leakage Current
at 15.6℃
μA/km/kV 6kV
Insulation Resistance
MΩ·km 6kV
Leakage Current
μA/km/kV DC Voltage Test
For 5 Minutes
mm2 AWG 3kV 6kV
16 5 4.62 4500 0.278 5400 0.246 27kV 35kV
20 4 5.19 3380 0.295 3869 0.262
33 2 6.54 2530 0.394 2922 0.328
42 1 7.35 2300 0.427 2658 0.361